Comfort-Aire PTHP15A130A User Manual
Page 5

Heat Controller
OWNER’S MaNual
Packaged Terminal A/C
4
SLEEVE INSTALLATION
Wall sleeve location
When making the wall opening, please observe the following requirements:
A) The air inlet and outlet should be unblocked so the air can be delivered to every corner of the room.
B) Install the unit in places that are away from heat or sources of flammable gases.
C) Do not install the unit in places that are subject to heavy dust.
D) Do not install the unit in places where the operational noise and exhausted air might trouble your neighbor.
E) There should be sufficient space around the unit to facilitate maintenance and repairs
(refer to Figs. 1 and 2).
INSTALLATION INSTRUCTIONS
To ensure that the unit operates safely and efficiently, it must be installed, operated and maintained according
to these installation and operating instructions and all local codes and ordinances or,in their absence, with the
latest edition of the National Electric Code (or CEC for Canadian Installations). The proper installation of this
unit is described in the following sections. Following the steps in the order presented should ensure proper
installation.
WARNING
HIGH VOLTAGE
DISCONNECT ALL POWER BEFORE SERVICING
OR INSTALLING THIS UNIT. MULTIPLE POWER
SOURCES MAY BE PRESENT, FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.
!
Dimension
Recommended installation clearance
D1
Projection of case into room - 1/2” minimum up to 1-3/4”
maximum without use of electrical sub-base.
Note: 2-3/8” minimum when sub-base is used.
D2
Height above finished floor or top of carpet - 1/2” minimum
2” recommended without sub-base - 3” minimum with sub-base.
Fig. 1
Fig. 2
WARNING
REMOVE FRONT PANEL, DO NOT DIRECTLY
TOUCH THE FIN.
!