Comfort-Aire PTHP15A130A User Manual
Page 4
![background image](/manuals/463439/4/background.png)
PACKAGED TERMINAL A/C
OWNER’S MaNual
Heat Controller
3
•
Fan Motors Permanently Lubricated - All units
have two fan motors for quiet operation and
maximum operating efficiency.
Motors are permanently lubricated to reduce
maintenance and totally enclosed to keep dirt and
water out of the motor windings.
•
Indoor Fan Speed Selections LOW /HIGH - Unit
may be operated in low fan speed or high fan
speeds. Some speeds may not be present based
on unit capacities.
•
Rotary Compressor - smoother operation for quiet,
dependable service and high efficiency.
•
Indoor Coil Frost Control - prevents indoor coil
from freezing. Frost can form on the Indoor coil
when the unit is operated in cooling when the
outdoor temperature is low. The unit automatically
shuts the compressor off until the indoor coil
temperature warms to the point where frosting will
no longer occur, then restarts the compressor.
•
LS Control (front-desk control) - The unit can
be turned ON/OFF by a front desk control switch.
The control wire, colored purple, locates in the wall
mounted thermostat interface (refer to Fig. 7 on
page 8).
The control logic as belows:
1. Turn ON unit: short circuit R and LS then release
one time within 5 seconds.
2. Turn OFF unit: short circuit R and LS then release
for twice within 5 seconds.
3. Force unit shut down for one time: connect LS to R
for over 5 seconds.
NOTE: After force shut down, you can turn the unit
ON again by hand-held remote controller or the
control panel.
•
Special control functions for DIP switches - The
DIP switches are on main board. No. 5 auto
heating (for units with heat). When unit is connected
to the power supply, and room temperature Is
lower than 10°C/50°F for 3 minutes, unit will start
heating automatically no matter what the setting
mode is. Only when room temperature reaches
13°C/55°F will heating stop.
ON position enables this function.
No. 6 -Electric Power-off Memory. After power on,
the unit will run the same settings as last time.
ON position enables this function. No. 7-Fan
CON/CYC for heating.
ON position enables continuous fan for heating. The
default setting Is fan cycled for heating.
No. 8 -Fan CYC/CON for cooling ON position
enables fan cycle for cooling. The default setting is
fan continuous for cooling.
WARNING: Before service, you must disconnect
the power cord to avoid electric shock! Do not
reprogram DIP switches No. 1 to No. 4, when
powered this could cause damage or fire. Power the
unit on again, the new function will be activated.
UNIT ACCESSORIES
This unit is designed for through-the-wall installation
in new or existing buildings. To complete the
installation of this PTAC, an insulated wall sleeve and
an outdoor grille (either the stamped aluminum
grille, or the architectural grille) are required.
Consult with your distributor to acquire any optional
accessories.
The chassis and the cabinet front are shipped in one
carton.
WARNING
HIGH VOLTAGE
DISCONNECT ALL POWER BEFORE SERVICING
OR INSTALLING THIS UNIT. MULTIPLE POWER
SOURCES MAY BE PRESENT,FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE,PERSONAL
INJURY OR DEATH.
!