beautypg.com

Goulds Pumps CV 3171 - IOM User Manual

Page 24

background image


24

CV 3171 IOM 05/11

 

Operating At Reduced Capacity

WARNING

DO NOT operate pump below
minimum rated flows or with
discharge valve closed. These

conditions may create an explosive hazard due
to vaporization of pumpage and can quickly
lead to pump failure and physical injury.

A centrifugal pump should never be operated
continuously near shut-off or zero capacity, or with
the discharge valve closed. To do so may shorten
the life of the pump and greatly increase down time
and maintenance.

CAUTION

Damage occurs from:

1. Increased

vibration

levels

-

affects

bearings, stuffing box or seal chamber, and
mechanical seal.


2. Increased radial loads – Stresses on shaft

and bearings.


3. Heat buildup - Vaporization causing

rotating parts to score or seize.


4. Cavitation - Damage to internal surfaces of

pump.

CAUTION

Serious damage may result if
the pump is run in the wrong
direction.

CAUTION

Operation of the unit without
proper lubrication will cause
bearing failure, and pump

seizure.

Operating At Reduced Head


On motor driven pumps, when discharge head is
dropped below the rated point, the motor should be
watched for overloading. If this condition is likely
to persist, arrangements should be made to either
manually or automatically throttle the discharge
valve to build up head to prevent overloading.

Operating With Surge Conditions


If pump is installed with a quick closing valve in the
discharge line that closes when the pump is
running, dangerous pressure surges may be built
up that can cause damage to the pump or line.
In services of this kind, some cushioning
arrangement must be provided to protect the
pumping equipment.


Operating Under Freezing Conditions

Exposure to freezing conditions while pump is idle
could cause liquid to freeze and damage the pump.
Liquid inside pump should be drained.


Final Alignment/Clearance Check

1. Run the unit under actual operating conditions

for a sufficient length of time to bring the pump
and driver up to operating temperature.


2. Check alignment while unit is still hot per

alignment procedure.


3. Reinstall coupling guard.

The coupling guard used in an
ATEX classified environment
must be constructed from a

non-sparking material.