MAINTENANCE OF BEARINGS

OIL LUBRICATED BEARINGS

Oil lubricated bearings must be lubricated at the job site.
Remove fill plug (408H) and add oil until level is at the
center of the sight glass (319). Replace fill plug (Fig. 21).

Change the oil after 200 hours for new bearings,
thereafter every 2000 operating hours or 3 months
(whichever comes first). Change more often if oil
becomes contaminated with dirt or water. Oil change
volumes are per

Table 3.

Table 3

Oil Volumes

Frame

Liters

Quarts

M

2

2.1

L

2

2.1

XL

3

3.2

A high quality turbine oil with rust and oxidation
inhibitors should be used. For the majority of operational
conditions, bearing temperatures will run between 60°C
(140°F) and 82°C (180°F). In this range, an oil of ISO
viscosity grade 68 at 40°C (105°F) is recommended. If
bearing temperatures exceed 82°C (180°F), use of ISO
viscosity grade 100 is recommended.

Table 4

Lubricating Oil Requirements

Bearing

temperature

below

82°C (180° F)

Bearing

temperature

above 82°C

(180° F)

ISO Grade

VG 68

VG 100

Approx. SSU at

38°C (100°F)

300

470

DIN 51517

C68

C100

Kinematic viscosity at

40°C (105°F) mm

2

/sec

68

100

Acceptable Oils

Exxon

Teresstic EP 68

Chevron

GTS Oil 68

Mobil

Mobil DTE 26 300 SSU
@ 38°C (100°F)

Gulf

Gulf Harmony 68

Phillips

Mangus Oil Grade 315

Phillips

MM motor oil SAE 20-20W

Phillips

HDS motor oil SAE 20-20W

If the constant level oiler option is supplied, it was
adjusted before leaving the factory (See

Operations

Section for details). Fill the outer bottle with oil and
replace in the oiler housing. Oil reservoir in bearing
frame is filled when oil remains visible in the bottle.
Several fillings of the bottle may be required.

26

3501 IOM 11/10

Fig. 21