Machine Cleaning
ALWAYS ENSURE THAT THE MACHINE IS SWITCHED
OFF PRIOR TO ANY MAINTENANCE.
!
!
After use, empty waste-water tank using emptying hose
and flush-out with clean water.
Next remove floor-tool vacuum hose and flush-out
with clean water.
Next empty clean water tank, using emptying hose
and again flush-out with clean water.
A
A
B
C
B
C
Before removing separator, first pull-off connected hoses.
Whilst pressing in the separator toggles, remove hood and rinse using clean water.
The hood also has a sealing-rubber which should be examined at every clean-down.
Remove white filter and rinse using clean water, and refit.
IMPORTANT:
Never use the machine without the recommended filter as it may cause damage to
the machine.
Remove debris basket filter and rinse using clean water, and refit.
IMPORTANT:
If the debris basket is allowed to become clogged, vacuum performance can deteriorate.
The clean-water tank filter is located to the rear of the battery compartment, and should
be checked at regular intervals. Lift white plug and remove white filter, rinse and refit.
Ensure tank has been emptied and care is taken when working in the vicinity of batteries.