beautypg.com

NaceCare Solutions ST765 User Manual

Page 12

background image






UPON COMPLETION OF WORK
After the operator is completed his/her work.

• Close the water valve (3)

• Raise the brush base (1)

• Raise the squeegee (2)









- Turn the brush switch off (1)
- Turn the vacuum motor switch off (2)
- Move the machine to the area where it is to be drained
- Turn the key switch off (3)










- Lift hood (1) and keep it lifted by rotating support (2) backwards. This

frees recovery tank drain tube (3).

- Remove the drain tube from its seat, unscrew the drain plug and empty

the recovery tank (Lift the right side of the tank a few centimeters to
accelerate final emptying phases). These operations must be performed
wearing rubber gloves to protect against contact with dangerous
solutions.

- Thesqueegee should be raised when the machine is not in use to

prevent permanent distortion of the rubber strips.






- Remove the brushes and clean them with a jet of water (see "BRUSH

REMOVAL" below).









This manual is related to the following products: