TurboChef Technologies i3 EN User Manual
Page 28
20
TROUBLESHOOTING
Issue
Possible Cause(s)
Resolution
F1: blower running
Status bad
- oven power interrupted.
- blower motor not running.
- Verify wall circuit breaker is on. reset the
breaker and then power the oven on.
- Place the oven in the off state and unplug
the oven – leave for two minutes. re-plug in
the oven, switch on the isolator/main power
supply, and press the “on/off” soft key.
- Call Customer Support.
F2: Cook
Temperature Low
- oven power interrupted.
- Air nozzles on the top/bottom
of the cook cavity are clogged.
- oven door is out of alignment.
- Defective heater.
- blower motor not running.
- oven not fully warmed up.
- Verify wall circuit breaker is on. reset the
breaker and then power oven back on.
- open oven door and verify the air nozzles
on the top/bottom of the cook cavity are
clean and not clogged.
- open and close the door several times and
verify oven door is closed.
- reset high-limit located in the bottom left
corner of the oven rear wall. If the problem
persists, call Customer Support.
- Call Customer Support.
- repeat warmup and allow oven to idle
for five minutes.
F3: Magnetron
Current Low
- Microwave circuit defective.
- Call Customer Support.
F4: Door Monitor
Defective
- oven door switches are out of
order.
- Call Customer Support.
F5: Magnetron over
Temperature
- blockage of cool air into the
oven.
- rear cooling fan exhaust
guard(s) clogged.
- remove anything that may be obstructing
the flow of cool air into the oven.
- Check rear fans to see if they are free of
debris. Clean as required.
F6: EC Temp
- blockage of cool air into the
oven.
- rear cooling fan exhaust
guard(s) clogged.
- remove anything that may be obstructing
the flow of cool air into the oven.
- Check rear fans to see if they are free of
debris. Clean as required.