beautypg.com

Pulsafeeder Pulsa GLM DM7 User Manual

Page 27

background image

27

DIFFICULTY

PROBABLE CAUSE

REMEDY

Delivery erratic

Leak in suction line

Locate and correct

Product cavitating

Increase suction pressure

Entrained air or gas in product

Consult factory for suggested venting

Motor speed erratic

Check voltage and frequency

Fouled check valves

Clean, replace if necessary

Inadequate backpressure

Increase discharge pressure to obtain a
minimum pressure difference of 5 psi from
suction to discharge

Delivery higher than rated

Suction pressure higher than discharge
pressure

Install backpressure valve or consult
factory for piping recommendations

Back pressure valve set too low

Increase setting

Vack pressure valve leaks

Repair, clean or replace

Noisy gearing, knocking

Discharge pressure too high

Reduce pressure

Water hammer

Install pulsation dampener

Low oil level

Examine sight glass on side of pump, add or

replace oil as required.

Piping noisy

Pipe size too small

Increase size of piping - install pulsation

dampener

Pip runs too long

Install pulsation dampener in line

Pulsation sampener inoperative or flooded

Refill with air or insert gas. Inspect and replace

diaphragm and recharge

No surge chamber or dampener used

Install pulsation dampener

Motor overheats

Pump overloaded

Check operating conditions against pump

design. Verify discharge pressure

High or low voltage

Check power source

Loose wire

Trace and correct

Incorrect motor wiring

Verify and correct

Oil level low

Check and add as cecessary