Wash pump will not operate, Overload trips – Power Soak 31990 PS-100 Owner's Manual User Manual
Page 24

20
Wash Pump Will Not Operate
Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:
LOOK FOR
CORRECTION
1
No water in sink
Fill sink with water
2
LIQUID LEVEL SENSOR dirty
Clean LIQUID LEVEL SENSOR
3
No incoming power to unit
Reset customer's breaker in
breaker control panel
4
Loose wires
Tighten wires
5
LIQUID LEVEL SENSOR setting is too low See page 21
6
Defective LIQUID LEVEL CONTROL
Checek and replace as necessary
Overload trips
LOOK FOR
CORRECTION
1
Low voltage to unit
Check with Volt meter whie running
2
Debris in PUMP intake
Clean
3
Debris in IMPELLER
Remove PUMP and clean
4
Defective CONTACTOR
Check and replace as necessary
5
Defective OVERLOAD
Check and replace as necessary
6
Defective PUMP MOTOR
If amp draw is greater than 10% of motor rating
and all of above check out, then replace MOTOR
If the above troubleshooting guidelines do not correct the problem, contact
Power Soak Systems at (816)222-2400.