beautypg.com

Wash pump will not operate, Overload trips – Power Soak 31990 PS-100 Owner's Manual User Manual

Page 24

background image

20

Wash Pump Will Not Operate

Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:

LOOK FOR

CORRECTION

1

No water in sink

Fill sink with water

2

LIQUID LEVEL SENSOR dirty

Clean LIQUID LEVEL SENSOR

3

No incoming power to unit

Reset customer's breaker in
breaker control panel

4

Loose wires

Tighten wires

5

LIQUID LEVEL SENSOR setting is too low See page 21

6

Defective LIQUID LEVEL CONTROL

Checek and replace as necessary

Overload trips

LOOK FOR

CORRECTION

1

Low voltage to unit

Check with Volt meter whie running

2

Debris in PUMP intake

Clean

3

Debris in IMPELLER

Remove PUMP and clean

4

Defective CONTACTOR

Check and replace as necessary

5

Defective OVERLOAD

Check and replace as necessary

6

Defective PUMP MOTOR

If amp draw is greater than 10% of motor rating
and all of above check out, then replace MOTOR

If the above troubleshooting guidelines do not correct the problem, contact
Power Soak Systems at (816)222-2400.