Component operation and checks, Programming the heater controller – continued – Power Soak SI-100 Owner's Manual User Manual
Page 30

29
Component Operation and Checks
Programming the Heater Controller – Continued
-----------------------------------------------------------
10 Push mode
"100" on top
"P L" on bottom
-----------------------------------------------------------
11 Push mode
"nor" on top
"dSP" on bottom
----------------------------------------------------------
12 Push mode
Actual temp on top
Set temp on bottom
-------------------------------------------------------------
If an accurate reference thermometer is available, measure the temperature in the wash
sink. Compare to the reading on the heat controller and note the difference. If, for
example, the heat controller reads 113 degrees and the reference thermometer reads 115
degrees, the difference would be +2. If the heat controller reads 115 degrees and the
reference thermometer reads 113 degrees, the difference would be -2
-------------------------------------------------------------
13 Push mode
"0" on top
"Pb 1" on bottom
------------------------------------------------------------
14 Push mode
The number noted in step 12 on top. If a reference
thermometer was not available, use "0"
"CAL" on bottom
------------------------------------------------------------
15 Push mode
"0" on top
"AUt" on bottom
____________________________________
16 Push mode
Actual temp on top
Set temp on bottom
------------------------------------------------------------
17 Push "up" and "down" arrows simultaneously for 5 seconds.
Display will read: "0" ON TOP
"LOC" on bottom
Change top reading to "3".
--------------------------------------------------------------
18 Repeat steps 2 through 12