29

Component Operation and Checks

Programming the Heater Controller – Continued

-----------------------------------------------------------

10 Push mode

"100" on top

"P L" on bottom

-----------------------------------------------------------

11 Push mode

"nor" on top

"dSP" on bottom

----------------------------------------------------------

12 Push mode

Actual temp on top

Set temp on bottom

-------------------------------------------------------------

If an accurate reference thermometer is available, measure the temperature in the wash

sink. Compare to the reading on the heat controller and note the difference. If, for

example, the heat controller reads 113 degrees and the reference thermometer reads 115

degrees, the difference would be +2. If the heat controller reads 115 degrees and the

reference thermometer reads 113 degrees, the difference would be -2

-------------------------------------------------------------

13 Push mode

"0" on top

"Pb 1" on bottom

------------------------------------------------------------

14 Push mode

The number noted in step 12 on top. If a reference

thermometer was not available, use "0"

"CAL" on bottom

------------------------------------------------------------

15 Push mode

"0" on top

"AUt" on bottom

____________________________________

16 Push mode

Actual temp on top

Set temp on bottom

------------------------------------------------------------

17 Push "up" and "down" arrows simultaneously for 5 seconds.

Display will read: "0" ON TOP

"LOC" on bottom

Change top reading to "3".

--------------------------------------------------------------

18 Repeat steps 2 through 12

The heat controller is programmed.