Pump works – Heater does not work

Look For

Correction

1 Loose wires

Tighten wires

2 Defective SWITCH

Check and replace as necessary

3 Defective HEAT ELEMENT

Check and replace as necessary

4 Defective HEAT CONTROL

Check and replace as necessary

5 Defective THERMOCOUPLE

Check and replace as necessary

6 Defective HEAT CONTACTOR

Check and replace as necessary

Intermittent running

Look For

1 See 2,5,6,7 under

Pump does not work - Heater does not work

2 See 5, 6 under

Pump does not work - Heater Works

Pump leaks

Look For

Correction

1 PUMP CASING PLUG loose or defective

Tighten or replace

2 Defective PUMP SEAL

Replace