Pump does not work – heater works, Overload trips – Power Soak SI-100 Owner's Manual User Manual

Page 21

background image

20

Authorized Service Agency Section

- Continued

Pump does not work – Heater works

Look For

Correction

1 Tripped OVERLOAD

Push red RESET bar on OVERLOAD

2 Loose wires

Tighten wires

3 Defective START or STOP switch

Check and replace as necessary

4 Defective CONTACTOR/OVERLOAD

Check and replace as necessary

5 TIMER settings incorrect

Check – See page 24

6 Defective TIMER

Check and replace as necessary

7 Defective PUMP MOTOR

Check and replace as necessary

Overload trips

Look For

Correction

1 Low voltage to unit

Check with Volt meter while running

2 Debris in PUMP intake

Clean

3 Debris in IMPELLER

Remove PUMP and clean

4 Defective CONTACTOR

Check and replace as necessary

5 Defective OVERLOAD

Check and replace as necessary

6 Defective PUMP MOTOR

If amp draw is greater than 10% of motor rating and all of above check

out, then replace MOTOR

7 Improper Thermal Units on Overload

Check. See wiring diagram for correct thermal unit for horsepower &

voltage. On some units, it is permissible to use the next size thermal

unit. Call Factory for details.