Pump does not work – Heater works
Look For
Correction
1 Tripped OVERLOAD
Push red RESET bar on OVERLOAD
2 Loose wires
Tighten wires
3 Defective START or STOP switch
Check and replace as necessary
4 Defective CONTACTOR/OVERLOAD
Check and replace as necessary
5 TIMER settings incorrect
Check – See page 24
6 Defective TIMER
Check and replace as necessary
7 Defective PUMP MOTOR
Check and replace as necessary
Overload trips
Look For
Correction
1 Low voltage to unit
Check with Volt meter while running
2 Debris in PUMP intake
Clean
3 Debris in IMPELLER
Remove PUMP and clean
4 Defective CONTACTOR
Check and replace as necessary
5 Defective OVERLOAD
Check and replace as necessary
6 Defective PUMP MOTOR
If amp draw is greater than 10% of motor rating and all of above check
out, then replace MOTOR
7 Improper Thermal Units on Overload
Check. See wiring diagram for correct thermal unit for horsepower &
voltage. On some units, it is permissible to use the next size thermal
unit. Call Factory for details.