Pump and heater do not work – Power Soak SI-100 Owner's Manual User Manual
Page 19

18
Facility Owner/Manager Section
The only troubleshooting procedure that the facility owner or
manager can perform is listed immediately below. All other
procedures must be performed by an authorized service agency. To
obtain the name of a recommended service agent in your area,
please call the Metcraft, Inc.
Power Soak
Service Department at
800-444-9624.
Pump and Heater do not work
Please perform the following in order:
• Drain the sink.
• Turn off the circuit breaker for your sink.
• Clean the liquid level sensor (LLS). To locate the LLS, first remove the baffle
located on the right or left inside wall (same side as control panel) of the wash sink.
The heater cover is held on with three wing nuts. The LLS is a white plastic disk
with a silver metal center mounted on the wall behind the heater cover. Clean with
warm soapy water and an abrasive pad or brush.
• Fill the sink.
• Turn on the circuit breaker for your sink.
• Start the sink.