beautypg.com

Pitco Frialator Multilane Three Basket Fryer Control User Manual

Page 5

background image

Programming Pitco P/N 60126805

Two and Three Basket Controller

5

L20-403 Rev 0 07/12

2.2.4

Hold Pre-Alarm

Hold Pre-Alarm is a timer setting that is used to warn operators that the Hold Time is about to
expire.
To use Hold Pre-Alarm, Hold Time must be set to a non-zero value, and Hold Pre-Alarm must be
set to a value less than Hold Time. Default value is zero, meaning the Hold Pre-Alarm is
inactive.
Display shows [nPA mm:ss] [TIME] where “n” is the key number, PA means Pre-Alarm, and
“mm:ss” is minutes and seconds.
Use the product keys for numeric entry, to adjust the current setting.
Press the [Clock] key to save cook time and continue setup for this product key.

Displays show [SELECT] [TIME]. Repeat steps from section 2.3.1 to make changes to any other
product keys or continue.

2.3

To Exit Level 1 programming

Display shows [SELECT] [TIME].
Press the [P] key.
Display shows [PROGRAM]. Continue to section 3 to change options, or, exit here in the
next step.
To exit Level 1 programming, press the [P] key again.
Displays will show [HEATING], [MELT] [LIQUID (or SOLID)], or [READY].

3

To Change Options:


Display must show [PROGRAM] from section 2 to change options. When the product key [10] is
pressed, display will show [SELECT] [OPTIONS]. Indicator lights above product keys will
illuminate to represent options that may be changed. Each option below uses the product key [10]
to scroll or toggle through available choices in the display. When the correct value is displayed,
press the [P] key to save choice. Display will again show [PROGRAM].

3.1

Fahrenheit or Celsius Display:

The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F.
With display showing [PROGRAM], press the product key [10].
Display shows [SELECT] [OPTIONS].
Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current setting.
Use the product key [10] to scroll through choices (F or C). Press [P] key to save choice.
Display shows [PROGRAM].

3.2

Password Change or Required?

With factory settings, a password is not required to enter programming Levels 1 and 2. The password may
be activated or changed in this section.
With display showing [PROGRAM], press the product key [10]. Display will show [SELECT]
[OPTIONS].
Press product key 2, display shows [SET PAS] [NEW PASS]. Use the product key [10] to scroll
through choices [NO PASS] or [PASS REQ]. Press [P] key to save choice.
If [NO PASS] is selected Display returns to [PROGRAM].
If [PASS REQ]. is selected, display show [PASSnnnn] [NEW PASS]. Displayed value “nnnn” is

the current password. Use the product keys for numeric entry, to change password. Press [P] key
to save choice. Display shows [PROGRAM].

Note: The factory default password (6684) will always work even if a different password is selected

above.