beautypg.com

How to replace diverter cartridge; fig. 11 & 12 – American Standard Selectronic Proximity Integrated Faucet with Optional Above Deck Mixing 705.215 User Manual

Page 7

background image

DISCONNECT

WIRE CONNECTION

6

M965255 REV. 1.6

1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW

(2) and pulling off the LEVER

HANDLE

(3). Unthread the FAUCET COVER SCREW

(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.

2. Disconnect WIRE CONNECTION (1) to SOLENOID
VALVE

(2). Fig. 9.

3. Unthread SOLENOID VALVE (2) from VALVE BODY
(

3). Fig. 9.

4. Remove FILTER SCREEN (4) from base of
SOLENOID VALVE

(2). Rinse clean and replace. Fig. 10.

5. Thread SOLENOID VALVE (2) into VALVE BODY (3)
and hand tighten. Reconnect WIRE CONNECTION

(1).

Fig. 9.

6. Replace FAUCET COVER (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET
COVER SCREW

(4) and tighten. See Fig. 2 in this

section.

HOW TO CLEAN FILTER SCREEN

ON SOLENOID VALVE; Fig. 9 & 10

5

1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW

(2) and pulling off the LEVER

HANDLE

(3). Unthread the FAUCET COVER SCREW

(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.

2. Pull out LIMITER STOP (1) from the VALVE STEM
(2). Unthread COLLAR NUT (3) from VALVE BODY (4).
Fig. 11.

3. Pull DIVERTER CARTRIDGE (5) out and replace
with new DIVERTER CARTRIDGE

(5).

NOTE: Make sure the two ALIGMENT PINS

(6) in the

base of the DIVERTER CARTRIDGE

(5) are facing

upward.

4. Replace FAUCET COVER (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET
COVER SCREW

(4) and tighten. See Fig. 2 in this

section.

HOW TO REPLACE DIVERTER

CARTRIDGE; Fig. 11 & 12

6

Fig. 9

1

2

3

Fig. 10

4

2

3

4

2

1

6

Fig. 11

Fig. 12

5

9

8