Diagnostics – Parking Light Flash Table

Flashes

Description

1

Doors locked, alarm and starter kill armed

Run time has expired

TRUNK

button pressed

Start signal received by the module

Cold weather mode cancelled

2

Remote start attempt cancelled by remote

Doors unlocked, starter kill disarmed

Exiting ignition valet

Power ON to OFF (automatic transmission)

Exiting remote valet

Power-up reset

Board set from manual to automatic; power

ON

2 slow flashes then

8 quick flashes

Reset from manual to automatic

3

• Entering ignition valet

• Entering or exiting ready mode

Entering remote valet

Entering extended run time

4

+12 V detected on the brake input wire

either while cranking or during run time

Entering multi-speed tach programming

• Board set from automatic to manual; power

ON

• Power ON to OFF ( manual transmission)

5 Fast

Tach signal programmed

New transmitter programmed

6

A remote start was attempted while a tach-before-crank signal was detected before cranking

8

Unit reset

10

A ground (-) signal was detected on the hood pin input wire wire when attempting to remote start

or during run time

When pressing

START/STOP

15 quick flashes

The parking brake is connected to ground (automatic transmission)

1 – pause – 2

There was a remote start attempt while the vehicle was in valet mode

Failed start: vehicle’s low battery voltage

…followed by 1 flash

Exiting cold weather mode

ON SOLID for 3

seconds….

…followed by 3 flashes

Entering cold weather mode

ON continuously

Idle mode: Idle mode is engaged

Run time: The vehicle has been remote started and is in run time.

ON 2 seconds

The hood has been opened and a ground (-) signal has been detected on the hood pin input

wire

ON 4 seconds

Locking or unlocking a door (with door pulses configured to 4 sec.)

ON 20 seconds

The hood pin has been flashed and you now have access to the programming options

Constant flashes

up to 60 sec.

In siren or horn mode: Alarm condition generated by an intrusion, by panic mode or when the

system is powered up