9 percentage mode, 1 storing a 100% mass – A&D Digital Platform Scales HW-10KGV User Manual
Page 25
HW-G Instruction Manual Page 23
HW-G OZIM v1a
9 Percentage Mode
The percentage mode is to display a mass value in the unit of “%”.
It is necessary to store a 100% mass value in advance to use this function.
9.1 Storing a 100% Mass
Step 1
Press the
MODE
switch to display the unit %.
Step 2
Press the
SET
switch to enter the mode that
stores a 100% mass.
Step 3
If necessary, with nothing on the pan press
the
ZERO
switch to display zero.
Step 4
Gently place the 100% mass onto the pan.
Press the
ENTER
switch to store the mass
after the stability mark is displayed. Then the
percentage unit is displayed.
Caution
When the sample is too light and it is not possible
to calculate a 100% mass, the scale displays
lo .
and returns to step 3.
Pressing the
ENTER
switch after
lo
is displayed,
the next unit is displayed.
Step 5
Remove all items from the pan.