Message lists, Warning messages – Sony VPL-VW95ES User Manual
Page 73
73
Oth
e
rs
When a warning indicator other than the above starts flashing, and the symptom persists even after
carrying out the above methods, consult with qualified Sony personnel.
Warning messages
ON/STANDBY flashes in
red. (A repetition rate of 5
times)
c The lens protector is not fully open. Turn the power of the
projector off and then on again. If the lens protector still does not
fully open, consult with qualified Sony personnel.
Tip
In an urgent situation, refer to the illustration below to open the lens
protector with your hands. Press the
?
/
1
(ON/STANDBY) switch to
turn the power on and operate the projector.
Note
Message Lists
Message
Cause and Remedy
High temp.! Lamp off in 1
min.
c Turn off the power.
c Check to ensure that nothing is blocking the ventilation holes
Frequency is out of range!
c Frequency is out of range. Input a signal that is within the
acceptable frequency range of the projector (
Please check Input-A
Signal Sel.
c Set “Input-A Signal Sel.” on the Setup
menu to
“Computer” when an RGB signal is input from a computer
(
Please replace the Lamp/
Filter.
c It is time to replace the lamp. Replace the lamp (1 page 75).
c Also, replace the air filter too. Restart cleaning the ventilation
holes (intake) (
If this message appears again after you replace the lamp and
filter, the lamp replacement process is not complete. Check the
lamp replacement process (
To clear this message, press any button either on the remote control
or the control panel of the projector once.