beautypg.com

American Dryer Corp. AD-115ES User Manual

Page 64

background image

60

For models with Johnson Controls DSI (Direct Spark Ignition) Module (G760)

Theory Of Operation;

Start the drying cycle. When the gas burner

ignites within the chosen trial for ignition time

(6-seconds), the flame sensor detects gas

burner flame and signals the Direct Spark

Ignition (DSI) module to keep the gas valve

open...as long as there is a call for heat. The

DSI module will “LOCKOUT” if the gas

burner flame is not sensed at the end of the

trial for ignition period. The trial for ignition

period will be repeated for a total of three (3)

retries/trials (the initial try and two [2] more

retries/trials). If the flame is not sensed at the

end of the third retry/trial (inter-purge period

of 30-seconds) the DSI module will

“LOCK-OUT” (L.E.D. [light emitting diode]

flashes).

A steady L.E.D. (light emitting diode) indicator

indicates normal operation.

indicates a power or an internal failure has occurred.

No L.E.D. (light emitting diode) indicator indicates