beautypg.com

American Dryer Corp. AD-115ES User Manual

Page 63

background image

59

a. Upon completing installation of the replacement

Direct Spark Ignition (DSI) module, reestablish

power to the dryer.

b. Starting the drying cycle.

c. The ignition (DSI) module’s L.E.D. indicator will

light “red” for up to approximately 1.5-seconds

(pre-purge time).

d. The module’s indicator light will then turn “green.”

The gas valve will be energized and the ignitor probe

will spark for approximately 8-seconds. The burner

flame should now be established.

e. With the burner flame on, remove the flame sensor

wire from the FS terminal of the DSI module.

f. The burner flame must shut off and the ignition

module must “LOCK-OUT” with the DSI module’s

indicator light “red.”

g. Stop the drying cycle, with the flame sensor wire

still removed, restart the drying cycle.

h. The ignition module must proceed through the pre-purge, with the indicator light “red,” the ignition trial

time of approximately 8-seconds, with the indicator light “green,” and then proceed to lockout with the

indicator light “red.”

i. Functional check of the Direct Spark Ignition (DSI) Module is complete.

1) Replace the flame sensor wire from the FS terminal to the DSI module.

2.

Direct Spark Ignition (DSI) System

For Direct Spark Ignition (DSI) System models manufactured with ADC Module Part No. 880815