b. Air Connection

Air connection to system --- 1/8-inch N.P.T.

c. No air regulation or filtration is provided with the dryer. External regulation and filtration of 80 PSI (552

kPa) must be provided. It is suggested that a regulator and filter gauge arrangement be added to the

compressed air line just before the dryer connection. This is necessary to insure that correct and clean air

pressure is achieved.

5. Steam Damper System Operation

The ADS-115ES steam damper, as shown in the top illustration, Diagram 1 (Heating Mode) on page 40,

allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper

is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying

process. When the damper is closed, ambient air is drawn directly into the tumbler (basket ), allowing a rapid

cool down.

Diagram 1 -- shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).

Diagram 2 -- shows the damper in the cool down (closed) mode, pulling ambient air directly into the tumbler

(basket) without passing through the coils.

NOTE: With the dryer off or with no air supply, the damper is in the Cool Down Mode as shown in

the top illustration, Diagram 2 on page 40.

4. Steam Damper Air System Connections

The ADS-115ES is manufactured with a pneumatic (piston) damper system which requires an external

supply of compressed air. The air connection is made to the steam damper solenoid valve which is located at

the rear inner top area of the dryer just above the electric service relay box.

a. Air Requirements

C

OMPRESSED

A

IR

S

UPPLY

A

IR

P

RESSURE

Normal

80 psi

552 kPa

Minimum Supply

70 psi

483 kPa

Maximum Supply

90 psi

621 kPa

Shaded areas are stated in metric equivalents.