beautypg.com

Karcher HDS 801 B User Manual

Page 24

background image

– 10

Nozzle is set to "CHEM"

Set nozzle to "High pressure".

Nozzle is blocked/ washed out

Clean/ replace nozzle.

Sieve in the water connection is dirty

Clean sieve.

Sieb in front of the water scarcity safe-
guard is dirty.

Clean sieve.

Amount of water supply is too low.

Check water supply level (refer to tech-
nical data).

Detergent tank is empty.

Top up detergent orset dosing value for
detergent to "0".

Detergent dosing valve is leaky.

Check dosing valve.

Safety valve is displaced.

Adjust safety valve (Customer Service).

Safety valve is leaky.

Replace the safety valve and/or the
washer (Customer Service).

Overflow valve is defective

Replace overflow valve (Customer
Service).

Air within the system

Vent pump:

Set dosing value for detergent to "0".

Open the water supply.

Start the engine according to the oper-
ating instructions of the engine manu-
facturer.

To dearate the appliance, unscrew the
nozzle and allow the appliance to run
until the water exits in a bubble-free
state.

Switch off the appliance and fit the noz-
zle again.

Nozzle is blocked.

Clean the nozzle.

Safety valve is displaced.

Adjust safety valve (Customer Service).

Nozzle is set to "High pressure"

Set nozzle to "CHEM".

Detergent suction hose with filter is

leaky or blocked

Check/ clean detergent suction hose

with filter.

Washer is defective.

Inform Customer Service.

Temperature limiter has got triggered

again.

Get the device checked by Customer

Service.

Fuel tank empty

Refill.

Water shortage

Check water supply, check connec-

tions, clean water shortage safeguard.

Fuel pump is defective

Replace fuel pump (Customer Service).

Fuel filter dirty

Change fuel filter.

No ignition spark

If device is in use and no ignition spark can

be seen through the viewing glas, have de-

vice checked by customer service.

Uneven spraying of fuel at the burner

nozzle

Clean fuel filter.

Water inlet is closed.

Open the water supply.

Amount of water supply is too low.

Increase water flow quantity.

Sieve blocked in the water shortage

safe guard.

Clean sieve in the water shortage safe

guard.

Valves in the high pressure pump are

leaky or dirty.

Inform Customer Service.

If malfunction can not be fixed, the device
must be checked by customer service.

Device is not building up pressure

Water jet is not uniform

Device is not sucking in detergent

Oil in the high pressure pump is

milky

Burner does not start

Water scarcity safeguard does not
switch on - no flame

24