Transport storage – Karcher Système de recyclage des eaux usées WRP 16000 User Manual
Page 21
-
9
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Only transport the gravel filter when
empty (gravel fill removed).
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
Only store the gravel filter when empty
(gravel fill removed).
Water in the recy-
cled water tank has
a bad odour
WRP was switched off during the night or
over the weekend
WRP must be ON continuously
Operator
none or very poor circulation, very little
ventilation
Turn the rotary switch of the circulation pump to
position "III".
Check if the circulation valve is open.
Operator
Check pipes for dirt and damage; clean or replace
them as required
Operator, Cus-
tomer Service
Check the ventilation, the ventilator must clearly
bubble in the pump basin.
Operator, Cus-
tomer Service
Continuous flow
sound
Float switch, control or fresh water sole-
noid valve defective
Check, repair or replace the concerned compo-
nent
Operator, Cus-
tomer Service
Immersion pump is
not functioning
Water level in the pump basis is too low
Washing system runs with fresh water until level
S15 top is reached. Find the cause.
Customer Ser-
vice
Float switch S7 defective
Check the float switch; clean, repair or replace it
as required
Operator, Cus-
tomer Service
Control head of multi-channel valve is de-
fective
Repair control head
Customer Ser-
vice
Controls are defective
Check, repair or replace controls
Customer Ser-
vice
Filter output is too
low
Shutoff valve recycled water closed
Open the shutoff valve recycled water.
Operator
Gravel filter is blocked
Backwash gravel filter or change the gravel. If the
fault recurs, call customer service.
Operator, Cus-
tomer Service
Immersion pump is blocked, defective
Clean, repair, replace immersion pump
Operator, Cus-
tomer Service
Pipe or valve is leaky, defective, blocked
Check pipes and valves; clean, repair or replace
as required
Operator, Cus-
tomer Service
Fresh water con-
sumption is too high
Float switch S9 is defective.
Replace
Customer Ser-
vice
Conductivity sensor (option) is defective or
contaminated.
Check; clean, replace, if required.
Customer Ser-
vice
Fresh water solenoid defective
Check the fresh water solenoid valve, replace if
required
Customer Ser-
vice
Fault
Possible cause
Remedy
By whom
Transport
Storage
21
EN