beautypg.com

Proper use environmental protection, Start up, Operation – Karcher Úpravna vody WPC 5000 CD User Manual

Page 14: Maintenance and care

background image

14

Deutsch

– The electrical connections must be

done by an electrician according to
IEC 60364-1.

– Never touch damaged or ripped mains

cables. If required, pull out the plug
from the socket immediately.

– Never operate the unit with damaged

cable.

The following symbols are used in this op-
erating manual:

ƽ

Danger

Indicates an immediate threat of danger.
Failure to observe the instruction may re-
sult in death or serious injuries.

Warning

Indicates a possibly dangerous situation.
Failure to observe the instruction may re-
sult in light injuries or damage to property.
Note
Indicates useful tips and important infor-
mation about the product.

The plant is used for treating surface wa-
ter, water from natural springs and river
water.
Due to the modular structure, turbid sub-
stances, hardeners, salts, bacteria and
water can be separated depending on the
quality of raw water.

ƽ

Danger

Risk of injury if the plant is not installed
properly. Risk to health on account of
poorly treated drinking water. The plant
may be put into operation only when set-
up, installed and prepared for operation by
skilled and authorized personnel.

Î

Check the connection of the plant to
the raw water source.

Î

Ensure uninterrupted flow of the gen-
erated drinking water into a tank or a
suitable user-side facility.

Note
The driking water must be able to flow out
without any counter-pressure. The height
difference must not be more than 3 m.

Note
If the plant is fitted with one or more dos-
ing stations, then it needs to be ensured
that this has been connected properly and
filled up.
Î

Fill up dosing station (refer chapter
"Maintenance and Care/ Maintenance
jobs")

Î

Check whether the mains plug of the
dosing pumps of the dosing stations is
connected to the sockets of the plant.

Î

Check the position of the operating
swtich:
"Automatic“ position: the plant is
controlled by an external floater switch
in the drinking water tank.
"Manual" position: the plant is man-
ually switched on and off using the
main switch.

Î

Turn the main switch to position "1";
drinking water production will start.

– Display time

Alternating display of:
– Plant/ version number and operating

status.

– Drinking water temperature and con-

ductance.

– Operating hours (_ _ _ _ _h_ _min).

Warning

Risk of damage. If the plant is to be shut
down for more than 14 days, then Kärcher
Customer Service must carry out some
preservative tasks.
Î

Turn main switch to "0"; the plant will
stop production of drinking water.

Note
Do not switch off the plant overnight! The
media filter is automatically cleaned dur-
ing the night. There is a risk of damage to
the plant if you do not do this cleaning.

ƽ

Danger

Health hazard on account of poor quality
of drinking water. . The control tasks out-
lined in this maintenance plan are to be
carried out according to the schedule in
order to ensure the quality of drinking wa-
ter. If the deviations in the target values
cannot be corrected by taking the pre-
scribed measures, then stop production of
drinking water and inform Kärcher Cus-
tomer Service immediately.

Electrical system

Symbols

Proper use

Environmental protection

The packaging material can be
recycled. Please do not throw
the packaging material into
household waste; please send
it for recycling.

Old appliances contain valuable
materials that can be recycled;
these should be sent for recy-
cling.. Batteries, oil, and similar
substances must not enter the
environment. Please dispose of
your old appliances using ap-
propriate collection systems.

Start up

Before Commissioning

Filling up the dosing station

Operation

Switching on the plant

Monitoring elements

Display media and active carbon filters

Display of the operating panel

Switching off the plant