beautypg.com

I n s ta l l at i o n – Alto-Shaam AR-7VH User Manual

Page 7

background image

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National

Electrical Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “

OFF

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed

by a licensed electrician in accordance with

applicable local electrical codes.

After wiring and power connection has been

completed, turn the main power switch to the “

ON

position. The main power switch can be left “

ON

for daily use, but should be turned “

OFF

” when

cleaning or performing maintenance or repairs to

the rotisserie.
REGARDING INTERNATIONAL

STANDARD UNITS:

If the unit is not equipped with flexible cord

with plug, an all-pole country approved

disconnection device which has a contact

separation of at least 3mm in all poles must be

incorporated in the fixed wiring for disconnection.

When using a cord without a plug, the

green/yellow conductor shall be connected to the

terminal which is marked with the ground symbol.

If a plug is used, the socket outlet must be easily

accessible. If the power cord needs replacement,

use a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock

hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts to

provide sufficient protection against potential

difference. The terminal is marked with the

following symbol.

E L E C T R I C A L C O N N E C T I O N

THE ROTISSERIE CAN BE HARD WIRED. PERMANENT
WIRING FOR ALL OVENS MUST BE INSTALLED BY A
LICENSED ELECTRICIAN IN ACCORDANCE WITH
APPLICABLE, LOCAL ELECTRICAL CODES.

230V ROTISSERIES FOR HARD WIRING MUST BE
EQUIPPED WITH

AN

EXTERNAL

MAIN

SWITCH

WHICH DISCONNECTS ALL POLES WITH A CONTACT
SEPARATION OF AT LEAST 3MM FOR ALL POLES.

“ WA R N I N G ” R I S K O F F I R E !

Use a UL Listed grounding type plug rated 250 Volts, 50
Amperes, 1 Phase, 3 wire for single phase units and 250 V,
50 A, 3 Phase , 4 wire for three phase units.

Plug to be

selected and installed only by qualified service personnel.
Individual

conductors

are

marked

L

1

,

L

2

,

L

3

when

applicable, N when applicable, and G.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

I N S TA L L AT I O N

A R - 7 E R o t i s s e r i e w i t h A R - 7 V H Ve n t l e s s H o o d O p e r a t i o n & C a r e M a n u a l • 6

D A N G E R

APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST BE
EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

E L E C T R I C A L

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

K

W

208 (

AGCY

)

1

60

40.0

8.3

BARE END

NO PLUG

230 (

AGCY

)

1

60

42.0

9.0

240 (

AGCY

)

1

60

38.0

8.8

208 (

AGCY

)

3

60

33.0/ph 8.3

BARE END

NO PLUG

230 (

AGCY

)

3

60

35.0/ph 9.0

240 (

AGCY

)

3

60

32.0/ph 8.8

380-415

(

AGCY

)

3

50/60

24.0/ph 8.8

NO CORD

NO PLUG

380

3

50/60

22.0/ph 7.4

415

3

50/60

24.0/ph 8.8