beautypg.com

Alto-Shaam AR-7VH User Manual

Page 25

background image

T R O U B L E S H O O T I N G G U I D E

ERROR

C O D E

D E S C R I P T I O N

/

R E S U LT S

P O S S I B L E C AU S E

S E RV I C E R E Q U I R E D

E-10

Air Sensor Fault (shorted)

Inoperative Oven

Air sensor defective?

AIR SENSOR TEST

Test air sensor by placing sensor in ice water bath. Use an
ohm meter set on the ohm scale. The reading should be 100
ohms resistance. The sensor must be replaced if the reading
is more than 2 ohms higher or lower.

E-11

Air Sensor Fault (open)

Inoperative Oven

E-30

Under Temperature

Oven will shut down

Door gasket need replacement?
Preheating procedure skipped?
Oven overloaded or frozen product used?
Defective air sensor?

E-31

Over Temperature

Oven will shut down

Defective air sensor?

AIR SENSOR TEST

Test air sensor by placing sensor in ice water bath. Use an
ohm meter set on the ohm scale. The reading should be 100
ohms resistance. The sensor must be replaced if the reading
is more than 2 ohms higher or lower.

E-70

Configuration Connector Error

Inoperative Oven

Check control connections for loose wires.

E-78

Voltage Low

Inoperative Oven

If 208-240 VAC, voltage is below 190 VAC. Correct.

E-79

Voltage High

Inoperative Oven

If 208-240 VAC, voltage is over 250 VAC.

Correct.

E-80

EEPROM - Function Data Error

Inoperative Oven

Contact factory for service.

E-82

EEPROM - Calibration Data Error

Inoperative Oven

Contact factory for service.

E-86

EEPROM - Preset Data Error

Inoperative Oven

Contact factory for service.

A R - 7 E R o t i s s e r i e w i t h A R - 7 V H Ve n t l e s s H o o d O p e r a t i o n & C a r e M a n u a l • 2 4