ADC ICX-250 User Manual
Page 32

Switches
Configuring the ICX-250 27
Issue 1, September 1998
ADCP-62-023
© 1998, ADC Telecommunications, Inc.
Switch Settings for FXS Port Transmit and Receive Attenuation
The table below represents the FXS port transmit and receive attenuation
(loss) control settings.
FXS Port
Switch
Number
3 dB Attenuation
9 dB Attenuation
Transmit
Receive
Transmit
Receive
1
S14
8 = OFF
7 = OFF
8 = ON
7 = ON
2
6 = OFF
5 = OFF
6 = ON
5 = ON
3
4 = OFF
3 = OFF
4 = ON
3 = ON
4
2 = OFF
1 = OFF
2 = ON
1 = ON
5
S15
8 = OFF
7 = OFF
8 = ON
7 = ON
6
6 = OFF
5 = OFF
6 = ON
5 = ON
7
4 = OFF
3 = OFF
4 = ON
3 = ON
8
2 = OFF
1 = OFF
2 = ON
1 = ON
9
S16
8 = OFF
7 = OFF
8 = ON
7 = ON
10
6 = OFF
5 = OFF
6 = ON
5 = ON
11
4 = OFF
3 = OFF
4 = ON
3 = ON
12
2 = OFF
1 = OFF
2 = ON
1 = ON
13
S17
8 = OFF
7 = OFF
8 = ON
7 = ON
14
6 = OFF
5 = OFF
6 = ON
5 = ON
15
4 = OFF
3 = OFF
4 = ON
3 = ON
16
2 = OFF
1 = OFF
2 = ON
1 = ON
17
S18
8 = OFF
7 = OFF
8 = ON
7 = ON
18
6 = OFF
5 = OFF
6 = ON
5 = ON
19
4 = OFF
3 = OFF
4 = ON
3 = ON
20
2 = OFF
1 = OFF
2 = ON
1 = ON
21
S19
8 = OFF
7 = OFF
8 = ON
7 = ON
22
6 = OFF
5 = OFF
6 = ON
5 = ON
23
4 = OFF
3 = OFF
4 = ON
3 = ON
24
2 = OFF
1 = OFF
2 = ON
1 = ON