Start up, Operation – Karcher KM 100-100 R Bp Pack User Manual
Page 21
-
5
Î
Open the hood, insert retaining rod.
Î
Disconnect pole terminal to negative
pole (-).
Î
Disconnect pole terminal to positive
pole (-).
Î
Remove the battery from the battery
holder.
Î
Dispose of the used battery according
to the local provisions.
Caution
Regularly check the fluid level in acid-filled
batteries.
– The acid in a fully charged battery has a
specific weight of 1.28 kg/l at a temperature
of 20 °C.
– The acid in a partially discharged battery
has a specific weight between 1.00 and
1.28 kg/l.
– The specific weight of the acid must be uni-
form in all cells.
Î
Unscrew all cell caps.
Î
Take a sample from each cell using the acid
tester.
Î
Put the acid sample back into the same cell.
Î
Where fluid level is too low, top up cells to
the mark provided with distilled water.
Î
Charge battery.
Î
Screw in cell caps.
ƽ
Danger
Risk of injury and damage! Do not use a
forklift to unload the appliance.
Note: Press the emergency-stop button to
immediately deactivate all functions and
turn the key switch to the "0" position.
To unload the machine, proceed as follows:
Î
Cut plastic packing belt and remove foil.
Î
Remove the elastic tape fasteners at
the stop points.
Î
Four indicated floor boards of the pallet
are fastened with screws. Unscrew
these boards.
Î
Place the boards on the edge of the pal-
let. Place the boards in such a way that
they lie in front of the four wheels of the
machine. Fasten the boards with
screws.
Î
Slide the four support beams included
in the packaging under the ramp.
Î
Remove the wooden blocks used for ar-
resting the wheels and slide them under
the ramp.
Î
Loosen immobilizing brake (see "move
sweep machine").
Î
Slide the machine over the prepared
ramp from the pallet.
Î
Connect battery (see section on Care and
maintenance)
Î
Release emergency-stop button by turning.
Î
Set programme switch to step 1 (driving).
Î
Set main switch to "1".
Î
Slowly drive the appliance off the ramp.
Î
Set main switch back to "0".
ƽ
Danger
Risk of injury! Before releasing the immobi-
lizing brake, the machine must be secured
to prevent it rolling away. After releasing
the immobilizing brake, the machine roles
without brakes.
Î
Remove the brake level from the wheel
and put it in its position.
The immobilizing brake is thus deactivated;
the machine can now be moved.
Î
Park the sweeper on an even surface.
Î
Remove the key.
Î
Check charging status of battery.
Î
Check side brush.
Î
Check roller brush.
Î
Shake off dust filter.
Î
Empty waste container.
Î
Check tyre pressure.
Note: For description, see section on Care
and maintenance.
Î
Open the hood, insert retaining rod.
Î
Release the wing nuts from the seat
rails.
Î
Slide the seat into the desired position.
Î
Tighten the wing nuts.
Note: If this adjustment is not enough, it
can be adjusted more.
Î
Remove 4 screws on the plate of the
seat contact switch.
Î
Remove the plate.
Î
Swivel the seat to the front.
Î
Loosen 4 screws on the seat support.
Î
Slide the seat and tighten the screws.
Î
Install the plate of the seat contact
switch.
– Indicator lamp glows green
Battery is charged.
– Indicator lamp glows yellow
Battery is almost discharged.
Î
Terminate the sweeping operation and
charge the battery.
– Indicator lamp blinks red
Discharging limit has been reached. Anoth-
er 3 minutes of driving operation remain;
then the appliance will switch off.
Î
The appliance cannot be restarted, the
battery must be charged for at least 3
hours.
– Indicator lamp glows red
Battery is discharged. The control has
switched off the sweeping system.
Î
Charge battery.
Remove the battery
Check fluid level in the battery and ad-
just if required
Unloading
(1) Machine without built-in battery
(2) Machine with built-in battery
Move the sweep machine
Start up
General notes
Inspection and maintenance work
Operation
Adjusting driver's seat
Check charging status of battery
21