Technical specifications
HDS 9/16-4
ST Gas
HDS 9/16-4
ST Gas LPG
HDS 12/14-4
ST Gas
HDS 12/14-4
ST Gas LPG
1.251-108
1.251-109
1.251-110
1.251-111
Performance data
Operating pressure of water (using standard nozzle)
MPa (bar)
16 (160)
16 (160)
14 (140)
14 (140)
Max. excess operating pressure (safety valve)
MPa (bar)
18,5 (185)
18,5 (185)
18,5 (185)
18,5 (185)
Water flow (can be regulated in a phase-less manner)
l/h (l/min)
500-1000 (8,3-
16,6)
500-1000 (8,3-
16,6)
600-1200 (10-
20)
600-1200 (10-
20)
Suction of detergent (can be regulated in a phaseless
manner)
l/h (l/min)
0-50 (0-0,8)
0-50 (0-0,8)
0-60 (0-1)
0-60 (0-1)
Water connection
Min. feed volume
l/h (l/min)
1100 (18,3)
1100 (18,3)
1300 (21,7)
1300 (21,7)
Feed pressure (min.)
MPa (bar)
0,1 (1)
0,1 (1)
0,1 (1)
0,1 (1)
Max. feed pressure
MPa (bar)
0,6 (6)
0,6 (6)
0,6 (6)
0,6 (6)
Electrical connection
Current type
--
3N~
3N~
3N~
3N~
Frequency
Hz
50
50
50
50
Voltage
V
380-420
380-420
380-420
380-420
Connected load
kW
6,4
6,4
7,5
7,5
Electrical protection (slow)
A
16
16
20
20
Type of protection
--
IPX5
IPX5
IPX5
IPX5
Protective class
--
I
I
I
I
Maximum allowed net impedance
Ohm
(0,381+j
0,238)
(0,381+j
0,238)
--
--
Power supply
mm
2
5 x 2,5
5 x 2,5
5 x 2,5
5 x 2,5
Temperature
Max. feed temperature
°C
30
30
30
30
Max. operating temperature of hot water
°C
98
98
98
98
Max. temperature safety thermostat
°C
110
110
110
110
Temperature increase during maximum water flow
°C
60-65
60-65
60-65
60-65
Gross heating performance
kW
75
75
95
95
Chimney draught
kPa
0,01-0,04
0,01-0,04
0,01-0,04
0,01-0,04
Gas connection values
Natural gas E (G 20)
m
3
/h
7,2
--
9,8
--
Natural gas LL (G 25)
m
3
/h
8,2
--
11,4
--
Rated connection pressure (natural gas)
kPa
1,8-5
--
1,8-5
--
Propane
kg/h
--
5,7
--
7,2
Rated connection pressure (Propane)
kPa
--
5-6
--
5-6
Environment data
Rated utilisation level
%
97
97
97
97
Standard emission factor NO
X
(natural gas G 25)
mg/kWh
< 40
--
< 40
--
Standard emission factor CO (natural gas G 25)
mg/kWh
< 40
--
< 40
--
Values for chimney dimensions
Suitability for excess pressure (min.)
kPa
0,05
0,05
0,05
0,05
Draught requirements
kPa
0
0
0
0
Exhaust flow - full load
kg/h
130
130
166
166
CO
2
(Natural gas)
%
9,5
--
9,5
--
CO
2
(Propane)
%
--
12
--
12
Exhaust temperature max./min.
°C
190/150
190/150
170/130
170/130
Combustion air/ air supply
Max. length: 10 n with two 90° arches (min. diameter 100 mm) From the in-
stallation room or fresh outside air - depending on the local regulations.
Condensate drain-out
Condensate drain-out (max.)
l/h
4 (via siphon
into the drain-
age system)
4 (via siphon
into the drain-
age system)
4 (via siphon
into the drain-
age system)
4 (via siphon
into the drain-
age system)
Connectiing piece
DN
40 (HTR)
40 (HTR)
40 (HTR)
40 (HTR)
Minimum water column, siphon
mm
300
300
300
300
29