Cold plate drink dispenser, Cold-plate drain water to bev-v drain water inlet – A.J. Antunes & Co BEV-V 9700924 User Manual
Page 2
![background image](/manuals/432746/2/background.png)
A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
Chill BEV-V iNSTAllATiON iNSTrUCTiONS (P/N 9700924)
1-877-392-7836 Fax: 630-784-1000
Page 2 of 2
P/N 1011074 Rev. B 11/10
Manifold Assembly to re-route Cold Plate
Melt Water From Tray
This manifold assembly only applies to cold plate drink water
dispensers that have the melt water drain lines emptying into
the soda overflow tray. For proper installation of the BEV-V, it is
necessary to re-route the cold plate drain lines underneath the
dispenser and into the BEV-V drain water inlet.
ICE
COLD PLATE
DRINK DISPENSER
Syrup Lines
CO
2
Water
Lines
Metal Cold Plate
Drain Nipples
Soda Overflow
Trough
Cold Plate
Cold-Plate Drain Water
To BEV-V
Drain Water Inlet
Figure 3. remove Tubing From Dispenser
Figure 4. Manifold Construction
SUGGESTED MATERIALS NEEDED:
• (2) 1/2” barbed tubing elbows
• (1) 1/2” barbed tubing T connector
• 6 feet 1/2” ID vinyl tubing
• (1) 1/2” tubing clamps
• (2) 1/2” L-shaped tubing turndowns as supplied with some
dispensers
1. Remove the front service panel to gain access to the cold
plate drain line outlets.
2. Remove all existing tubing from the exit points on the cold
plate, as shown in Figure 3.
3. Construct a manifold as shown in Figure 4 to re-route the
cold plate melt water under the dispenser, following the
syrup lines, and under the cabinet to be attached to the
BEV-V drain water inlet.
4. Use tubing clamps to secure any tubing connections.
3. Connect the cold plate drain line to the Drain Water Inlet
on the BEV-V unit using vinyl tubing or PVC pipe.
NOTE: if using vinyl tubing, make sure there are no pinches
or kinks in the tubing.
NOTE: The cold plate drain line should be insulated to keep
water as cold as possible before it enters the unit and to
prevent condensation.
NOTE: Because the cold plate drain line is gravity fed, you
should minimize any obstructions to the flow in the tubing.
4. Turn off the fresh water supply valve.
5. Turn off or unplug the carbonator.
6. Relieve the line pressure by depressing the soda valve.
7. Locate the filtered CO2 water line from the carbonator
and connect the line to the BEV-V CO2 Water Inlet.
8. Connect the pre-chilled BEV-V CO2 Water Outlet to the
cold plate with an insulated line.
9. Turn on the fresh water supply and the carbonator.
10. Check for any water leaks.