General

If you experience any problems with these instructions,

contact the Technical Service Department at 630-784-1000 or

toll free in the U.S. at 877-392-7854.

Warranty information

All ICE-1000, ICE-1800, and ICE-H units will be free from defects

in materials and workmanship for a period of three years.

Connections

FrESh WATEr CONNECTiONS
Chill ICE units use Super Speedfit® tubing fittings for fresh water

line connections that require no tools. Tubing (copper or plastic) is

simply inserted into the fitting collet to create a secure connection.
The tubing should be inserted approximately 3/4” (1.91 cm) until

it bottoms completely in the fitting to ensure there will be no

leaks. The tubing end to be inserted should be straight and have

a clean round cut. If the tubing is out-of-round, then carefully

make a new cut before inserting into the fitting.
SUmP WATEr CONNECTiONS
Chill ICE units require the use of 3/4” (1.91 cm) PVC pipe for

the sump water connections. It is important to glue all connec-

tions with the multipurpose glue. Follow the specific installation

procedures to make certain there will not be a vacuum block or

any reduction in water flow to the floor drain.

installation

To ensure material compatibility, a multipurpose glue for ABS, PVC,

and CPVC must be used. This will ensure a proper bond between

the 3/4” PVC and the black ABS Sump Water Discharge Inlet.
1. Turn off the ice machine and water supply valve.
2. Install the Chill ICE unit behind or to the side of the ice

machine bin at least 6 inches (15 cm) beneath the height of

the machine’s Sump Water Discharge Outlet (Figure 3).

Figure 1. Connections

Figure 2. Secure Connections

Figure 3. installation of Chill iCE

SUGGESTED MATERIALS AND EQUIPMENT NEEDED:
• (10 ft.) 3/4” PVC Pipe

• (5) 3/4” PVC Elbow Fitting

• (1) 3/4” PVC Tee Fitting

• (10 ft.) Copper Tubing

ICE-1000, ICE-1800: 3/8” OD

ICE-H: 1/2” OD

• (2) Brass Tubing Unions

ICE-1000, ICE-1800: 3/8” OD

ICE-H: 1/2” OD

• Multipurpose glue for ABS, PVC, and CPVC

• Tubing Cutter

• PVC Pipe Cutter

• Screwdriver or Drill with Bits

• Channel-Lock Pliers

• Adjustable Wrench

• Measuring Tape

Fresh Water Outlet

(To Ice Machine)

Sump Water Discharge Inlet

(From Ice Machine)

Sump Water Outlet

(To Floor Drain)

#3

#4

#2

Fresh Water Inlet

(From Wall or Filter)

#1

Cut the tube square and push past
the O-ring to the tube stop

Secure connections are simple

Tube is secured in position

Disconnection is just as easy

Push collet against body

Slide tube out of fitting