A.J. Antunes & Co C-420 9700904 User Manual
General, Equipment setup
carbon filter complete (p/n 9700900 or p/n 9700904)
1-877-392-7854 Fax: 630-784-1000
Page 1 of 4
P/N 1010961 Rev. B 03/12
TOOLS:
• Mounting Hardware (Not Provided)
• Drill with Bits
• Tape Measure
• Pipe Wrenches
• Adjustable Wrenches
• Level
• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord
• Screwdriver (Flat Blade and Phillips)
• Two Gallon Bucket
• Fresh 6% unscented liquid chlorine bleach
PARTS INCLUDED:
1 - Carbon Housing, Clear (P/N 2180232) or
Carbon Housing, White (P/N 2180283)
1 - Carbon Filter Head Bracket with Filter Head Screws
(P/N 0504359)
1 - Carbon Element Kit - Single (P/N 7000669)
1 - Filter Wrench (P/N 2180226)
1 - Installation Instructions (P/N 1010961)
caution
Do not use this system with water that is microbiologi-
cally unsafe or of unknown quality without adequate
disinfection installed before or after the system.
General
If you experience any problems with these instructions, or if any
parts are damaged or missing, contact the factory Technical
Service Department at 630-784-1000 or toll free in the U.S. at
877-392-7854.
The Carbon Filter Kit improves the quality of the water by
removing chlorine, tastes, and odors. The Carbon Filter Kit must
be installed upstream of all consumable water access points.
equipment Setup
When installing the kit, pay attention to the following guidelines:
• Do NOT install above electrical equipment.
• Allow space below the Carbon Housing for Carbon Element
change out.
plumbinG
note: this carbon filter Kit is designed to be used on tap
water not to exceed 104°f (40°c) or 100 psig (690 kpa). the
kit must be connected to the colD water line. Do not
connect the kit to the hot water line.
The Carbon Filter Kit has the following connections:
• Inlet
1” NPT and 1-½” NPT
• Outlet
1” NPT and 1-½” NPT
When making a plumbing connection to the kit, use a back-
up wrench on the supporting plumbing. Always use a quality,
approved pipe sealant or thread seal tape on the pipe threads.
Be careful not to get the pipe sealant inside the pipe when mak-
ing connections.
DO NOT over tighten the connections. The use of plastic fittings
when connecting to the plastic head will reduce the possibility of
cracking the head due to over tightening.
If soldered plumbing is used, do NOT apply heat to, or near, the
filter head. The use of union (O-ring seal) connections is highly
recommended for ease of installation and future servicing.
caution
this equipment must be installed to comply with the
basic plumbing code of the building officials and code
administrators, inc. (boca) and the food Service
Sanitation manual of the food and Drug administration
(fDa).
caution
Water pressure must not exceed 100 psig (690 kpa). to
reduce water pressure, install a water pressure regulator
and set the water pressure to below 100 psig (690 kpa).
Carbon
Housing
Carbon
Element
Head
Carbon
Element Kit
(single)
Carbon Filter
Head Bracket
(Filter Head Screws
NOT shown)
Filter
Wrench
figure 1. carbon filter Kit
a. J. antuneS & co. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188