beautypg.com

A.J. Antunes & Co C-420 9700904 User Manual

General, Equipment setup

background image

carbon filter complete (p/n 9700900 or p/n 9700904)

1-877-392-7854 Fax: 630-784-1000

Page 1 of 4

P/N 1010961 Rev. B 03/12

TOOLS:

• Mounting Hardware (Not Provided)

• Drill with Bits

• Tape Measure

• Pipe Wrenches

• Adjustable Wrenches

• Level

• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord

• Screwdriver (Flat Blade and Phillips)

• Two Gallon Bucket

• Fresh 6% unscented liquid chlorine bleach

PARTS INCLUDED:
1 - Carbon Housing, Clear (P/N 2180232) or

Carbon Housing, White (P/N 2180283)

1 - Carbon Filter Head Bracket with Filter Head Screws

(P/N 0504359)

1 - Carbon Element Kit - Single (P/N 7000669)

1 - Filter Wrench (P/N 2180226)

1 - Installation Instructions (P/N 1010961)

caution

Do not use this system with water that is microbiologi-

cally unsafe or of unknown quality without adequate

disinfection installed before or after the system.

General

If you experience any problems with these instructions, or if any

parts are damaged or missing, contact the factory Technical

Service Department at 630-784-1000 or toll free in the U.S. at

877-392-7854.

The Carbon Filter Kit improves the quality of the water by

removing chlorine, tastes, and odors. The Carbon Filter Kit must

be installed upstream of all consumable water access points.

equipment Setup

When installing the kit, pay attention to the following guidelines:

• Do NOT install above electrical equipment.
• Allow space below the Carbon Housing for Carbon Element

change out.

plumbinG
note: this carbon filter Kit is designed to be used on tap

water not to exceed 104°f (40°c) or 100 psig (690 kpa). the

kit must be connected to the colD water line. Do not

connect the kit to the hot water line.

The Carbon Filter Kit has the following connections:

• Inlet

1” NPT and 1-½” NPT

• Outlet

1” NPT and 1-½” NPT

When making a plumbing connection to the kit, use a back-

up wrench on the supporting plumbing. Always use a quality,

approved pipe sealant or thread seal tape on the pipe threads.

Be careful not to get the pipe sealant inside the pipe when mak-

ing connections.

DO NOT over tighten the connections. The use of plastic fittings

when connecting to the plastic head will reduce the possibility of

cracking the head due to over tightening.

If soldered plumbing is used, do NOT apply heat to, or near, the

filter head. The use of union (O-ring seal) connections is highly

recommended for ease of installation and future servicing.

caution

this equipment must be installed to comply with the

basic plumbing code of the building officials and code

administrators, inc. (boca) and the food Service

Sanitation manual of the food and Drug administration

(fDa).

caution

Water pressure must not exceed 100 psig (690 kpa). to

reduce water pressure, install a water pressure regulator

and set the water pressure to below 100 psig (690 kpa).

Carbon

Housing

Carbon

Element

Head

Carbon

Element Kit

(single)

Carbon Filter

Head Bracket

(Filter Head Screws

NOT shown)

Filter

Wrench

figure 1. carbon filter Kit

a. J. antuneS & co. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188