A.J. Antunes & Co TAC-02 9700906 User Manual
General, Equipment setup
![background image](/manuals/432741/1/background.png)
TAC-02 SySTem (P/N 9700906)
1-877-392-7854 Fax: 630-784-1000
Page 1 of 2
P/N 1011030 Rev. A 03/12
TOOLS:
• Mounting Hardware (Not Provided)
• Drill with bits
• Tape Measure
• Pipe Wrenches
• Adjustable Wrenches
• Level
• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord
• Screwdriver (Flat Blade and Phillips)
• Two Gallon Bucket
• Fresh 6% unscented liquid chlorine bleach
PARTS INCLUDED:
1 - Bracket, Filter Std. Housing w/ screws (P/N 0505639)
1 - Housing, Bowl, and Head (2180285)
1 - Wrench, Filter (2180244)
1 - Tee 3/4” NPT (2190184)
1 - Nipple 3/4” NPT x 1-1/2” Lg. (2070117)
1 - TAC-02 Cartridge Kit (7000716)
1 - Instruction Sheet (P/N 1011030)
CAuTioN
Do NoT use this system with water that is microbiologi-
cally unsafe or of unknown quality without adequate dis-
infection installed before or after the system.
General
If you experience any problems with these instructions, or if any
parts are damaged or missing, contact the factory Technical
Service Department at 630-784-1000 or toll free in the U.S. at
877-392-7854.
The TAC System improves the quality of water by addressing
scale issues on hot water applications. It should be installed
upstream of equipment using hot water.
equipment Setup
When installing the system, pay attention to the following guide-
lines:
• Do not install above electrical equipment.
• Allow space below the TAC Housing for TAC Cartridge
replacement.
PLumBiNG
NoTe: This system is designed to be used on tap water not
to exceed 100°F (38°C) or 100 psig (690 kPa). The kit must
be connected to the CoLD water line. Do NoT connect the
kit to the hot water line.
The TAC System has the following connections:
• Inlet
3/4” NPT
• Outlet
3/4” NPT
When making a plumbing connection to the System, use a
back-up wrench on the supporting plumbing. Always use a
quality, approved pipe sealant or thread seal tape on the pipe
threads. Be careful not to get the pipe sealant inside the pipe
when making connections.
Do NOT over tighten the connections. The use of plastic fittings
when connecting to the plastic head will reduce the possibility of
cracking the head due to over tightening.
If soldered plumbing is used, do NOT apply heat to, or near, the
Head. The use of union (O-ring seal) connections is highly
recommended for ease of installation and future servicing.
CAuTioN
This equipment must be installed to comply with the
basic plumbing code of the Building officials and Code
Administrators, inc. (BoCA) and the Food Service
Sanitation manual of the Food and Drug Administration
(FDA).
CAuTioN
Water pressure must not exceed 100 psig. To reduce
water pressure, install a water pressure regulator and set
the water pressure to below 100 psig.
Head
Bracket
and
Screws (8)
Housing
Head
O-Ring
(incl. with Head)
TAC
Cartridge
Filter Wrench
Figure 1. TAC-02 System
A. J. ANTuNeS & Co. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188