Chill BEV-V iNSTAllATiON iNSTrUCTiONS (P/N 9700924)

1-877-392-7836 Fax: 630-784-1000

Page 1 of 2

P/N 1011074 Rev. B 11/10

General

If you experience any problems with these instructions,

contact the Technical Service Department at 630-784-1000

or toll free in the U.S. at 877-392-7854.

Warranty information

All BEV-V units will be free from defects in materials and

workmanship for a period of three years.

General Specifications

CO2 Water Connections

3/8” (0.95 cm) barbed fittings

with 360° swivel

Drain Water Connections

3/4” (1.91 cm) PVC fittings

Operating Pressure

Min. 30 psi (2.1 kgf/cm²)

Max. 150 psi (10.5 kgf/cm²)

Electrical Connections

None

installing the BEV-V

To ensure material compatibility, a multipurpose glue for ABS,

PVC, and CPVC must be used. This will ensure a proper bond

between the 3/4” PVC and the black ABS Drain Water Inlet.
The BEV-V is furnished with an assortment of plumbing fittings

and insulating tape to aid in installation. However, due to the

variety of equipment and numerous methods of making

connections, all fittings may not be used.
NOTE: Do NOT attach the soda drip tray line to the BEV-V.

The excess soda in the drip tray should drain separately to

the floor drain. The BEV-V should only be attached to the

cold plate drain line that contains the melted ice water.
Before installing the BEV-V, you must determine how to route the

cold plate drain line to the unit. Some dispensers route the cold

plate drain line(s) into the syrup drip tray. You will need to separate

the cold plate drain water from the drip tray by routing a new drain

line underneath the dispenser to the BEV-V (See page 2 for sug-

gested manifold assembly to redirect cold plate drain water).

Figure 1. Typical installation

Figure 2. Specifications Diagram

ICE

COLD PLATE

DRINK DISPENSER

Syrup Lines

Floor Drain

Syrup

Drain

Cold Plate

Drain

Counter

Filtered

CO

2

Water

Pre-Chilled
CO

2

W ater

Max

Drain

CO

2

Water Inlet

(From Carbonator)

CO

2

Water Outlet

(To Cold-Plate)

Drain Water Inlet

(From Cold-Plate)

Drain Water Outlet

(To Floor Drain)

22 inches

(55 cm)

Thermal

Insulation

1. Place the BEV-V unit under the countertop where it is

intended to be installed and secure the unit in place with

the included mounting straps.

2. Use 3/4” PVC tubing to direct the Drain Water Oulet of the

BEV-V unit to the floor drain.

SUGGESTED MATERIALS AND EQUIPMENT NEEDED:
• (10 ft.) 3/4” PVC Pipe

• (4) 3/4” PVC Elbow Fitting

• Multipurpose glue for ABS, PVC, and CPVC

• Tubing Cutter

• PVC Pipe Cutter

• Screwdriver or Drill with Bits

• Channel-Lock Pliers

• Adjustable Wrench

• Measuring Tape
NOTE: Do NOT use copper tubing for the CO2 water line.