5. Attach the cold-plate melt line to the 3/4” Drain Water

Inlet. This line can be vinyl tubing or PVC pipe.

NOTE: if using vinyl tubing, make sure there are no pinches

or kinks in the tubing.
NOTE: This line should be insulated to keep the water as

cold as possible before it enters the unit and prevent con-

densation.
NOTE: Because the cold plate drain line is gravity fed, you

should minimize any obstructions to the flow in the tubing.
6. Turn off the fresh water supply valve.
7. Turn off or unplug the carbonator.
8. Relieve the line pressure by depressing the soda valve.
9. Locate the filtered CO2 water line from the carbonator

and connect the line to the BEV-D CO2 Water Inlet as

indicated on the unit.

10. Connect the pre-chilled BEV-D CO2 Water Outlet to the

cold plate with an insulated line.

11. Turn on the fresh water supply and the carbonator.
12. Check for water leaks.