5. Attach the cold-plate melt line to the 3/4” Drain Water
Inlet. This line can be vinyl tubing or PVC pipe.
NOTE: if using vinyl tubing, make sure there are no pinches
or kinks in the tubing.
NOTE: This line should be insulated to keep the water as
cold as possible before it enters the unit and prevent con-
densation.
NOTE: Because the cold plate drain line is gravity fed, you
should minimize any obstructions to the flow in the tubing.
6. Turn off the fresh water supply valve.
7. Turn off or unplug the carbonator.
8. Relieve the line pressure by depressing the soda valve.
9. Locate the filtered CO2 water line from the carbonator
and connect the line to the BEV-D CO2 Water Inlet as
indicated on the unit.
10. Connect the pre-chilled BEV-D CO2 Water Outlet to the
cold plate with an insulated line.
11. Turn on the fresh water supply and the carbonator.
12. Check for water leaks.