NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

615

455

315

200

SQ CM

3967

2935

2032

1290

MINIMUM ROUND
DUCT DIAMETER

IN

28

24

20

16

CM

71

61

50

40

!

!

Electrical Information _______________

Electrical Requirements

It is your responsibility to have all electrical connections
made by a properly licensed and competent electrician to
assure that the electrical installation is adequate and
conforms to local and state regulations or codes. In the
absence of such codes, all electrical connections,
material, and workmanship must conform to the applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION or in Canada, the Canadian Installation
Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-
B149.2-M91 (L.P. Gas) or LATEST EDITION.

Important

Failure to comply with these codes or
ordinances, and/or the requirements stipulated in

this manual can result in personal injury or component
failure.

Note

Component failure due to improper installation
will void the warranty.

Each dryer should be connected to an independently
protected branch circuit. The dryer must be connected with
copper wire only. Do not use aluminum wire, which could
cause a fire hazard. The copper conductor wire/cable must
be of proper ampacity and insulation in accordance with
electric codes for making all service connections.

Note

The use of aluminum wire will void the warranty.

Wiring diagrams are affixed to the inside at the top front
control door and the rear upper back guard/panel.

Electrical Service Specifications
Gas and Steam Models Only

* 3-Wire is available.

8/8/08

!

!

!

Gas and Steam

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT:

NOTES: A.

B.


C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.

When fuses are used they must be dual element, time delay, current

limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

208

3

13.7

20

220

3

10.4

20

230

3

11.6

20

240

3

10.8

20

380

4*

5.9

15

400

4*

5.9

15

416

4*

5.9

15

460

3

6.6

15

480

3

6.6

15

NOTE 1 Opening must be 2-inches (5.08 cm) larger than the duct (all the

way around). The duct must be centered within this opening.

NOTE 2 Distance should be 2 times the diameter of the duct to the nearest

obstruction.

Note

When the exhaust ductwork passes through a
wall, ceiling, or roof made of combustible

materials, the opening must be 2-inches (5.08 cm) larger
than the duct (all the way around). The duct must be
centered within this duct.

Important

For extended ductwork runs, the cross section
area of the ductwork can only be increased to an

extent. Maximum proportional ductwork runs cannot
exceed 20 feet (6.09 meters) more than the original
limitations of 20 feet (6.09 meters) with two elbows.
When the ductwork approaches the maximum limits as
noted in this manual, a professional HVAC firm should be
consulted for proper venting information.

Exhaust back pressure measured by a manometer in the
exhaust duct must be no less than 0 and must not exceed
0.3 in WC (0.74 mb).

The ductwork should be smooth inside with no projections
from sheet metal screws or other obstructions, which will
collect lint. When adding ducts, the duct to be added should
overlap the duct to which it is to be connected. All ductwork
joints must be taped to prevent moisture and lint from
escaping into the building. Inspection doors should be
installed at strategic points in the exhaust ductwork for
periodic inspection and cleaning of lint from the ductwork.

Multiple Dryer Venting 16-Inch (40.64 cm)

Diameter Minimum Exhaust Connections at Common Duct

A = 48-3/4” (123.82 cm)
B = 20 feet (6.09 meters)