Basic operations – Nikon Speedlight SB-700 User Manual
Page 32
Operation
B
B–7
Basic Operations
This section covers basic procedures in i-TTL mode in combination with
a CLS-compatible camera.
v
Notes on continuous fl ash photography
To prevent the SB-700 from overheating, allow it to cool down for at
•
least 10 minutes after 15 times of continuous firing.
When continuous flash firing is repeated in quick succession,
•
the internal safety function adjusts the recycling time by up to
15 seconds. If flash firing continues, the thermal cut-out indicator
appears on the LCD and all operations are suspended. (0E-31) Allow
it to cool down for several minutes to disable this function.
The conditions under which the internal safety function is activated
•
differ depending on the temperature and the SB-700 flash output
level.