Troubleshooting

Your kettle is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make

in the event of a problem. Wiring diagrams are furnished inside the service panel and in this manual.

If an item on the list is

followed by x, the work should be done by a qualified service representative.

SYMPTOM

WHO

WHAT TO CHECK

X indicates items which must be performed by an authorized technician.

Kettle will not heat, and
heating indicator will not
come on.

User

a. Electric power supply to the unit.
b. Water level in jacket.
c. Control circuit fuses in the control console.
REPLACE BLOWN FUSES ONLY WITH A FUSE OF THE
SAME AMP RATING. A HIGHER RATED FUSE WILL NOT
PROTECT THE UNIT OR THE BUILDING.

Auth Service

Rep Only

d. For loose or broken wires. X
e. Operation of variable thermostat. X
f. Low water cutout switch. X
g. Water probe. X
h. That high limit pressure switch is closed. X

Kettle will not heat, but
heating indicator comes on.

User

a. For air in the jacket. See “Jacket Vacuum” in the
Maintenance section of this manual.

Auth Service

Rep Only

b. Contactor. X
c. Heater elements with ohmmeter for ground short or open
element. If element is defective, call Manufacturer. X

Kettle continues heating
after it reaches the desired
temperature.

User

a. Thermostat dial setting.

Auth Service

Rep Only

b. Thermostat circuit for short. X
c. Thermostat calibration.
d. Thermostat operation. The thermostat should click when the
dial is rotated above and below the setting for the
temperature of the kettle. X
e. Contactor, to determine whether it is energized or stuck. X

Kettle stops heating before
it reaches the desired
temperature.

User

a. Thermostat dial setting.
b. Jacket Water level.

Auth Service

Rep Only

c. Thermostat calibration. X
d. Thermostat operation. Thermostat should click when the
dial is rotated above and below the setting for the
temperature of the kettle. X
e. Pressure limit switch.

Kettle heats slowly.

User

a. For air in the jacket. See “Jacket Vacuum” in the
“Maintenance” section of this manual.

Auth Service

Rep Only

b. Heater elements with ohmmeter for ground short or open
element. If an element is defective, call Manufacturer. X
c. Voltage of main power source. X

WARNING

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY AN AUTHORIZED SUPPLIER/DISTRIBUTOR