Layer 3 Switching

63

Rapier Switch Software Release 2.2.1
C613-02013-00 Rev A

Novell IPX

The advanced feature licence AT-RPFL3Upgrade is required for this feature.

The switch’s implementation of the Novell IPX protocol uses the term circuit to
refer to a logical connection over an interface, similar to an X.25 permanent
virtual circuit (PVC) or a Frame Relay Data Link Connection (DLC). The term
interface is used to refer to the underlying physical interface, such as VLAN,
Ethernet, Point-to-Point (PPP) and Frame Relay.

To create IPX circuit 1 with the Novell network number 129 over the admin
VLAN, use the command:

ADD IPX CIRC=1 INTERFACE=vlan11 NETWORK=129 ENCAP=802.3

The command:

SHOW IPX CIRCUIT

displays information about the circuits configured for IPX (Figure 20).

Figure 20: Example output from the SHOW IPX CIRCUIT command.

IPX CIRCUIT information

Name ......................... Circuit 1

Status ....................... enabled

Interface .................... vlan11 (802.3)

Network number ............... c0e7230f

Station number ............... 0000cd000d26

Link state ................... up

Cost in Novell ticks ......... 1

Type20 packets allowed ....... no

On demand .................... no

Spoofing information

Keep alive spoofing .......... no

SPX watch dog spoofing ....... no

On SPX connection failure .... UPLINK

On end of SPX spoofing ....... UPLINK

RIP broadcast information

Change broadcasts ............ yes

General broadcasts ........... yes

General broadcast interval ... 60 seconds

Maximum age .................. 180 seconds

SAP broadcast information

Change broadcasts ............ yes

General broadcasts ........... yes

General broadcast interval ... 60 seconds

Maximum age .................. 180 seconds

Filter information

Filters ...................... none