Electrical Safety and Installation Requirements

LIGHTNING DANGER
DANGER

: DO NOT WORK on equipment or CABLES during periods of LIGHTNING

ACTIVITY.

INSTALLATION

ELECTRICAL—TYPE CLASS 1 EQUIPMENT

THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired
earth ground socket outlet. An improperly wired socket outlet could place hazardous
voltages on accessible metal parts.

ELECTRICAL—CORD NOTICE

Use power cord, maximum 4.5 meters long, rated 6 amp minimum, 250V, made of HAR
cordage molded IEC 320 connector on one end and on the other end a plug approved by the
country of end use.

CAUTION

: Air vents must not be blocked and must have free access to the room ambient air

for cooling.

FUSE RATING

For continued protection against risk of fire replace only with the same type and rating of
fuse.

OPERATING TEMPERATURE

This product is designed for a maximum ambient temperature of 40 degrees C.

ALL COUNTRIES

: Install product in accordance with local and National Electrical Codes.