Command packet description, Record/zone2 status response packet, Data description – Lexicon DC-2 User Manual
Page 16: Get system parameter definition

Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol
Printed on: 10/19/00
16 of 44
Application Header:
Command
DC_CMD_GET_REC_STATUS
0x17
Data Count
0
0x00
Application Data:
N/A
7.3.6.2 Record/Zone2 Status Response Packet
Application Header:
Command
DC_RESP_REC_ZONE2_STATUS 0x82
Data Count
5
0x05
Application Data:
Data[0]
Zone2 Volume
nn
Data[1]
Assigned Input
nn
Data[2]
Zone2 Mute Active
nn
Data[3]
Record Active
nn
Data[4]
Zone2 Balance
nn
7.3.6.3 Data Description
Zone2 Volume:
Data Type:
Unsigned 8 bit integer.
Maximum Value:
92
Conversion:
0 = -80 dB
92 = +12 dB
Assigned Input:
Indicates the input that is currently assigned for the record/zone2 outputs.
Data Type:
Unsigned 8 bit integer.
Definition:
Zone2 Active:
Data Type:
Boolean.
TRUE:
Zone2 Outputs are active.
FALSE:
Zone2 Outputs are not active.
Record Active:
Data Type:
Boolean.
TRUE:
Digital Record Output is active
FALSE:
Digital Record Output is not Active.
Zone 2 Balance:
Data Type:
Unsigned 8 bit integer.
Maximum Value:
32
Conversion:
0 = Left
32 = Right
7.3.7 Get System Parameter Definition
There are two ways to request a DC-2/MC-1 system parameter definition. The first is by Parameter Id and
the second by parameter name. DC-2/MC-1 will respond with “System Parameter Definition Packet”.
7.3.7.1 Get System Parameter Definition by Id Command Packet
Error! Not a valid link.
7.3.7.2 Data Description
ParamId:
DataType:
Unsigned 8 bit integer