Get system status, Command packet description, System status response packet – Lexicon DC-2 User Manual
Page 14: Data description

Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol
Printed on: 10/19/00
14 of 44
TimeStamp:
Is a null terminated ASCII text string describing the build date and time of the
current ROM. The Format of this text string is:
“yy/mm/dd(sp)hh:mm”
yy- is the last two digits of the year (i.e. year 1999 = 99, year 2000 = 00)
mm - is the month
dd- is the day
(sp) - is an ASCII space character (0x20)
hh - is the hour
mm - is the minute
7.3.5 Get System Status
Request to DC-2/MC-1 for it’s current system status. DC-2/MC-1 will respond with “System Status
Packet”.
7.3.5.1 Command Packet Description
Application Header:
Command
DC_CMD_GET_SYS_STATUS
0x16
Data Count
0
0x00
Application Data:
N/A
7.3.5.2 System Status Response Packet
Application Header:
Command
DC_RESP_SYS_STATUS
0x81
Data Count
10
0x0A
Application Data:
Data[0]
System Volume
nn
Data[1]
Current Input
nn
Data[2]
Current EffectId
nn
Data[3]
Current Input Sample Rate
nn
Data[4]
Current Input Format
nn
Data[5]
Mute Active
nn
Data[6]
Effect Bypass Active
nn
Data[7]
Left/Right Balance
nn
Data[8]
Front/Back Balance
nn
Data[9]
Video Synch
nn
7.3.5.3 Data Description
System Volume:
Data Type:
Unsigned 8 bit integer.
Maximum Value:
92
Conversion:
0 = -80 dB
92 = +12 dB
Current Input:
Data Type:
Unsigned 8 bit integer.
Definition:
Current EffectId: