Step-by-step installation guide
13
Step-by-step installation guide
NOTE: The house duct is needed to connect to the
exhaust adaptor after installation completion.
B1. ADAPTING mICROWAVE BLOWER
FOR RECIRCULATION
2. Lift up the
blower plate.
1. Remove and save screw
that holds blower plate to
microwave.
Back of
Microwave
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
3. Remove screw holds blower mortor and
carefully pull out the blower unit. The wires will
extend far enough to allow you to adjust the
blower unit.
blower mortor screw
CAUTION: Do not touch blade of blower for
preventing crack and break. Hold outer case when
the blower pull out or back into.
4. Roll the blower unit 90 ° so that fan blade
openings are facing toward the front of the
microwave.
Back of
Microwave
Back of
Microwave
Before Roll
After Roll
5. Place the blower unit back into the opening.
CAUTION: Do not pull or stretch the blower unit
wiring. Make sure the wires are not pinched.
6. Secure blower unit to microwave with the screw.
B2. INSTALLING THE CHARCOAL
FILTER
1. Remove screws on top of grille using a #1
Phillips screwdriver.
2. Open the door.
3. Remove the grille.
• After push left, Pull the grille straight off.
Charcoal
Filter
4. Install the charcoal filter. When properly installed,
the wire mesh of the filter should be visible from
the front.
5. Reinstall the grille and the screws.
6. Close the door.
Insert mesh-side up
A. OUTSIDE TOP EXHAUST (VERTICAL DUCT)
B. RECIRCULATING (NON-VENTED DUCTLESS)
SMH8165_XAA DE68-03587A-04-EN_120725.indd 13
2012-07-25 �� 8:05:30