Fault
Cause
Remedy
E-No. 108 >
See E-No. 102
See E-No. 102.
Carriage doesn’t close properly.
Shipping safety screw screwed in
Remove shipping safety screw.
E-No. 110 >
See E-No. 102
See E-No. 102.
Carriage doesn’t close or closes too slowly.
E-No. 112 >
See E-No. 102
See E-No. 102.
as E-No. 108 Dual loop almost completed.
E-No. 114 >
Film chips or splicing tape chips in film channel
Remove chips, clean film guide parts and remove
Dual loop cannot be completed.
or film emulsion deposits
emulsion deposits.
on film guide parts.
E-No. 120 >
See E-No. 102
See E-No. 102.
Film channel cannot be closed completely.
E-No. 122 >
See E-No. 114
See E-No. 114.
Last frame of dual loop
cannot be totally pulled in.
E-No. 124 >
Control error.
Repeat procedure several times.
Film channel opens again
If fault still exists after several attempts
slightly after closing.
(indicated by E-No. 124) call ARRI Service station.
T