Trouble-shooting – ARRI LOCPRO 35 User Manual
Page 59
59
Fault
Cause
Remedy
HTI lamp dark after ignition
Thermofuse in ballast
Switch on unit for cooling
or in lamp housing has reacted
(without switching on HTI lamp).
Allow 2 minutes for cooling off, then briefly switch
off and on with mains switch. Re-ignite HTI lamp.
Ventilation fans not operating
Call service engineer.
HTI-Lamp “ON” but not functioning
Master Control Knob not in “0” position
Turn Master Control Knob to “0” position
Electronics disturbed
Carry out mains reset.
Switch unit off for approx. 30 seconds.
Then switch on again and start new ignition attempt.
If this fails, call service engineer.
HTI lamp defective
Replace HTI lamp
(experienced personnel only).
Fuse defective
Call service engineer.
Keyboard illumination and/or display dark
Control voltage failure
Call service engineer
T
rouble-Shooting