Serial Interface (X1)
An ASCII terminal or a personal computer with terminal
emulation program can be connected to the serial interface.
This makes it possible to check and change the operating
parameters.
Some image processing programs allow the integration of
control commands which are transmitted to the serial
interface.
Connection of PC or terminal via 1:1 connected interface
cable (no zero modem cable, no crossed connections).
Setting values
of serial computer interface
Baud rate: ................................ 9600 Baud/S
Data format: ............................. 8 bit, no parity, one start- and one stop bit
Plug type: ................................. 25 pin D-sub socket
Pin configuration: ...................... see annex ”Interfaces”
Command Outline
RFX .......................................... Run Forward
Function:
Forward running at selected projection speed.
Parameters (50 Hz Version)
X =
0
1
2
3
4
5
6
fps
50
25
12.5
6.25
3.12
1.56
0
Parameters (60 HzVersion)
X =
0
1
2
3
4
5
6
fps
60
30
15
7.5
3.75
1.87
0
Note:
This applies only for standard settings (50/50 and 60/60). If these are
changed by “Mode” function (Telecine Mode or Pulldown Mode) then
this frame rate is dominating. See Chapter 6.4.2.
RRX .......................................... Run Reverse
Function:
Reverse running at the selected projection
speed
Parameters 50 Hz and 60 Hz version see table
RFX.