Trouble-shooting – ARRI LOCPRO 35 User Manual
Page 56

56
Fault
Cause
Remedy
Mains “ON” without function
Mains voltage failure?
Connect to another electrical socket
unit will not operate
and check.
Mains cable connected to projector?
Check mains connection
and replace mains cable if necessary
Primary fuses defective
Replace fuses
(F1, F2, mains socket)
(see service instructions)
Projector voltage different from mains voltage
Check mains voltage setting on name plate.
If different from actual mains,
have service engineer make necessary change.
Important: Change name plate!
Inform ARRI-Service-Workshop
Rotating shutter not operating “E152”
Lamp cover not in position
Attach lamp cover, and clean
or safety switch not actuated.
actuation opening for safety switch
Temperature sensor in lamp housing
Switch on unit for cooling
has responded
(without switching on HTI lamp).
Allow 2 minutes for cooling off,
then briefly switch off and on
with mains switch. Ignite HTI lamp again.
T
rouble-Shooting