4 goesstatus read error register, Goesstatus read error register, 3. goesstatus command 2: read last message status – Campbell Scientific TX320 Transmitter User Manual
Page 33

TX320 Transmitter
forward power, reflected power, etc. Also returned is the GPS derived Latitude
and Longitude, which is updated once a day. The GPS update interval can be
changed.
TABLE 7-3. GoesStatus Command 2: Read Last Message Status
Index Contents
1
Command Result Code
2
Message type: Self-timed or Random
3
Size of message in bytes
4
Forward power in tenths of watts
5
Reflected power in tenths of watts
6
Power supply voltage under full load, in tenths of volts
7
GPS acquisition time in tens of seconds
8
Oscillator drift (signed, hundreds of Hz)
9 Latitude
degrees
10 Latitude
minutes
11 Latitude
seconds
12 Longitude
degrees
13 Longitude
minutes
14 Longitude
seconds
7.5.2.4 GoesStatus Read Error Register
Example:
Public Errors(10)
GoesStatus(Errors(), 4)
Command 4 (Read Error Register) is used to return the total number of errors
that have occurred, and codes describing the last four errors. When the
command that caused the error is listed as 31, the error is an internal fault.
Otherwise the error is just a communication error.
TABLE 7-4. GoesStatus Command 4: Read TX320 Error Registers
Index Contents
1 Result
Code
2 Number
of
Errors
3
Command that Caused the Error
4 Error
Code
5
Command that Caused the Error
6 Error
Code
7
Command that Caused the Error
8 Error
Code
9
Command that Caused the Error
10 Error
Code