TB4 and TB4MM Rain Gage

'Main Program
BeginProg
Scan

(1,Sec)

'TB4 Rain Gage measurement Rain-mm

PulseCount

(Rain_mm,C2,2,0,.254,0)

; Black wire connected to C2

'Call Data Tables and Store Data

CallTable

(Rain)

NextScan
EndProg

5.2.3 CR10X Control Port Example

Although this program is for the CR10X datalogger, our CR500, CR510, and
CR23X are programmed similarly.

;{CR10X}
*Table 1 Program
01: 1.0000 Execution

Interval

(seconds)


1: Pulse (P3)
1: 1

Reps

2: 8

Control Port 8 (switch closure only) ;Black wire connect to C8

3: 2

Switch Closure, All Counts

4: 1

Loc [ Rain_mm ]

5: .254

Multiplier

6: 0

Offset


2: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


3: Set Active Storage Area (P80)
1: 1

Final Storage Area 1

2: 101

Array

ID


4: Real Time (P77)
1: 1220

Year,Day,Hour/Minute (midnight = 2400)


5: Sample (P70)
1: 1

Reps

2: 1

Loc [ Rain_mm ]


*Table 2 Program
01: 0.0000 Execution

Interval

(seconds)


*Table 3 Subroutines

End Program