Campbell Scientific SDM-CAN Datalogger to CANbus Interface User Manual
Page 73
Appendix D. Examples of CAN Data Frames and Data Encoding and Decoding
40bit data frame with one 32bit IEEE floating point value MSByte first
Rxed Bit order within bytes
87654321 87654321 87654321 87654321 87654321
Rxed Byte order
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Values
A
Bit order within values
32 25 24 17 16 9 8 1
Value byte order
Exponent
Mantisa
Start bit (parameter 09:) RH ref
40 33 32 25 24 17 16 9 8 1
Start bit (parameter 09:) LH ref
1 8 9 16 17 24 25 32 33 40
Start bit (parameter 09:) Right Hand reference.
1: SDM-CAN (P118)
1: 0
SDM
Address
2: 1
Time-quanta
3: 5
Tseg1
4: 2
Tseg2
5: 1000
ID
Bits
0..10
6: 0000
ID
Bits
11..23
7: 00
ID
Bits
24..28
8: 5
Rx,
real
IEEE4,
MSB
1st
9: 1
Start
Bit
No.
10: 32
No.
of
Bits
11: 1
No.
of
Values
12: 1
Loc [ value_A ]
13: 1.0
Mult
14: 0.0
Offset
Start bit (parameter 09:) Left Hand reference.
2: SDM-CAN (P118)
1: 00
SDM
Address
2: 1
Time-quanta
3: 5
Tseg1
4: 4
Tseg2
5: 1001
ID
Bits
0..10
6: 0000
ID
Bits
11..23
7: 00
ID
Bits
24..28
8: 5
Rx,
real
IEEE4,
MSB
1st
9: 40
-- Start
Bit
No.
10: 32
No.
of
Bits
11: 1
No.
of
Values
12: 1
Loc [ value_A ]
13: 1.0
Mult
14: 0.0
Offset
D-11